top of page
blue-gradient-banner.png

Empore™ StageTips

The original micro-purification solution for proteomics - trusted by researchers for more than 20 years

Proteomics Optimized

Pre-packed & Ready

High Reproducibility

StageTips_redesigned_cover_catlog_number covered.png

Built on Empore™ Membrane SPE TechnologyThe same high-quality Empore™ membrane trusted by proteomics researchers worldwide. Pre-packed in chemically resistant micropipette tips for immediate use - no manual preparation neededLearn more about SPE technology →

Technical Specifications

Tip Volume

10 µL, 100 µL, 200 µL

Standard Packing

2 layers

Pack Size

96 tips, 384tips

Case Size

960 tips (10 packs)

Tip Material

Polypropylene

Chemical Resistance

Common organic solvents

Shelf Life

Around 3 years at room temperature

Max Layers

Up to 6 layers

Why Choose Empore™ StageTips?

Save time and improve reproducibility with standardized, pre-packed tips

Save Time

Get StageTips pre-packed and avoid manual preparation in the lab. Eliminate the hours spent punching disks and packing tips - focus on your research instead.

Superior Reproducibility

Standardized packing ensures consistent tip-to-tip performance, avoiding the variability encountered during manual preparation. Achieve reliable results across all experiments.

Universal Compatibility

Chemically resistant polypropylene tips work with all organic solvents and acidic/basic conditions needed for protein and peptide desalting and fractionation.

Flexible Options

Mix and match up to 6 layers of different sorbent phases. Available with single sorbents or pre-configured multi-layer combinations for specialized applications.

Cost Effective

Save money by ordering StageTips by the case (960 tips). Standard 200 µL volume with 96 tips per pack provides excellent value for high-throughput labs.

Proven Performance

More than 20 years of trusted use in proteomics labs worldwide. The original StageTip technology that researchers rely on for critical applications.

Empore™ C18 StageTips Operation Steps

Complete peptide cleanup in under 30 minutes with our validated 5-step protocol - from sample preparation to MS-ready peptides

StageTip C18 Desalting Step Snapshot_edited.png

1

Conditioning

  1. Filter through 50 – 100 µL of methanol without letting all solution pass, keeping the membrane wet. Discard filtrate.

  2. Repeat conditioning if membrane has gone dry.

  3. For centrifugation processing we recommend 1,000 – 1,500 x g for all steps.

StageTip C18 Desalting Step Snapshot_edited.png

2

Equilibrating

  1. Filter through 50 – 100 µL of 0.5% trifluoroacetic acid without letting all solution pass, keeping the membrane wet. Discard filtrate.

  2. Restart protocol at conditioning if membrane has gone dry.

StageTip C18 Desalting Step Snapshot_edited.png

3

Sample loading

  1. Put StageTip into a new collection tube and pipette sample into StageTip. Maximum volume of 400 µL. 40 µg maximum recommended peptide mass per C18-HD StageTip.

  2. Pass all solution through membrane and keep filtrate for troubleshooting problems.

  3. Optionally, user may pass the sample filtrate through an additional time, which may improve retention.

StageTip C18 Desalting Step Snapshot_edited.png

4

Washing

  1. Put StageTip into a new collection tube.

  2. Filter through 50 – 100 µL of 0.5% trifluoroacetic acid.

  3. Filter through 50 – 100 µL of 0.5% acetic acid.

  4. Depending on the level of contaminants in the sample, more wash steps may be necessary.

StageTip C18 Desalting Step Snapshot_edited.png

5

Sample eluting

  1. Put StageTip into a new collection tube for your analyte.

  2. Filter through 10 – 30 µL of 80% acetonitrile, 0.5% acetic acid, in water.

  3. Repeat step 5b one to two more times to elute all the analyte.

  4. Elution volume for high recovery may depend on how many micrograms of sample loaded. At maximum capacity, 100 µL total over a few elutions may be necessary.

  5. The sample is clean and ready for further concentration followed by mass spectrometry analysis.

Proven Protocols

Protocol for micro-purification, enrichment, pre-fractionation and storage of peptides for proteomics using StageTips

CDS Analytical continues to manufacture the same, high quality Empore membrane that has been trusted by researchers for their StageTip needs for nearly 20 years. Our standardized production ensures consistent performance across all batches.

"Protocol for micro-purification, enrichment, pre-fractionation and storage of peptides for proteomics using StageTips"

Rappsilber J., Mann M. & Ishihama Y. - Nature Protocols (2007)

Stagetips Selection Guide

Choose the optimal size for your sample volume and application

10 µLm vs 200 µL Disk Selection Guide

10 µL

Micro-Scale Analysis

  • Sample volume: 0.1-10 µL

  • Ultra-sensitive proteomics

  • Single-cell applications

  • 96 tips per pack

200 µL

Standard Processing

  • Sample volume: 10-200 µL

  • Routine proteomics workflows

  • Peptide fractionation

  • High-throughput processing

  • 96 tips per pack

Empore™ Stagetips Performance

Quantitative results demonstrating superior reproducibility

Layout 18_edited.png
Layout 18_edited.png

Applications

Optimized for proteomics and peptide analysis workflows

Proteomics Sample Preparation

  • Peptide desalting before MS

  • Buffer exchange

  • Removal of detergents

  • Concentrate Sample

Peptide Fractionation

  • SCX fractionation

  • SAX fractionation

  • High pH RP fractionation

  • 2D LC preparation

Biomarker Discovery

  • Plasma/serum peptide profiling

  • Urine peptidome analysis

  • CSF protein digests

  • Tissue extract cleanup

Metabolomics

  • Small molecule cleanup

  • Lipid extraction

  • Metabolite fractionation

  • Sample storage

Quantitative Proteomics

  • TMT/iTRAQ sample prep

  • SILAC workflow support

  • Label-free quantification

  • DIA sample preparation

A single disk. Endless possibilities

With a wide range of specialized membranes, including Anion, C18, C8, Cation Exchange, Chelating, SDB-XC, and Filter + C18 Sorbent Particles, each disk is engineered for precise applications, unlocking a world of potential

Picture5.jpg

Resources for StageTips

Download technical documents and application notes

Using the Empore™ C18 StageTips for High pH Peptide Fractionation in Global Proteomics

Evaluation of the Sample Loading Amount for Four Types of StageTips on Total Number of Protein Identifications in Proteomics

Evaluation of Different Empore™ StageTips for Proteomics Applications

Send Us a Message


Need More Information?
Let's Connect!

Our technical experts are ready to help you select the right Empore products for your specific applications and provide comprehensive support.

bottom of page